3421 S Halsted Place
Chandler, AZ 85286
602-283-2507

Local Reviews
for cave creek, az

Rated 4.8 out of 5 stars based on 19 customer reviews

Excellent Service

Early, new exactly what to do. Finished very quickly.


Response from Affordable Appliance Repair:

Thank you for the review, Meryl!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great service and response

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very professional and answered all my questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service


Response from Affordable Appliance Repair:

RANDY, Thank you so much!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Five stars

He did a great job


Response from Affordable Appliance Repair:

Richard, Thank you so much!!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Experienced Tech, Fixed the Problem


Response from Affordable Appliance Repair:

Bud, We appreciate your business very much, thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very knowlegable, pleasant, easy to work with.

Would not hesitate to choose Appliance Repair again.....


Response from Affordable Appliance Repair:

Avril, Thank you for taking the time to post this, it is greatly appreciated.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!!

I always get the best of service from Affordable Appliance Repair. I have been in my house for 8 1/2 years and they have always been on time and extremely professional when they come to my house. I would highly recommend them!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very helpful

Joey went above and beyond to help with my washer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Certom

Great service, showed up on schedule and completed the repair in minimum time. Price was fair and honest.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

We had a problem with our garbage disposal. It was repaired quickly without having to replace it, saving a lot of money! Joseph was very personable and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service and expected price.

Very nice and professional service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, even better communication

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for cave creek, az

Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection. Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal. No leaks upon completion.


Seth J.

Seth J. Job Checkin

CONCERN: Customer reports refrigerator deli drawer broke CAUSE: right side drawer support broken CORRECTION:customer had new support, installed new support


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports refrigerator section is not getting cold but freezer is still working properly. CAUSE: Found back panel and evaporator coils covered in frost. Tested the refrigerator defrost bi-metal thermostat for continuity, refrigerator defrost bi-metal continuity failed test. Refrigerator defrost bi-metal has electrical short. CORRECTION: Defrosted refrigerator evaporator coils and replaced defrost bi-metal thermostat. Operation now normal. CONCERN: Refrigerator section is not getting cold. DIAGNOSTIC AND CAUSE: Inspected voltage from terminal block to compressor, voltage normal at the time of inspection. Tested compressor operation, compressor operation normal at the time of inspection. Inspected voltage to evaporator fan motor, voltage normal at the time of inspection. Found evaporator fan motor failed. CORRECTION: Replaced refrigerator evaporator fan motor and tested. Operation now normal. CONCERN: Refrigerator is not working properly. DIAGNOSTIC AND CAUSE: In


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection. Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker LABOR ONLY and tested. Operation now normal. No leaks upon completion.


David R.

David R. Job Checkin

CORRECTION: Replaced door hinges per customer request, he supplied parts.


Spencer B.

Spencer B. Job Checkin

CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Spencer B.

Spencer B. Job Checkin

CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports dryer will not tumble clothes CAUSE: Found dryer belt failed CORRECTION: Replaced dryer belt and tested. Operation now normal.


Joseph J.

Joseph J. Job Checkin

CONCERN: Customer reports Glass Cooktop burner is not working CAUSE: Found burner element failed. CORRECTION: Replaced and tested, operation now normal. NOTE: Burner element receptacle is in good working order at the time of inspection. Infinite switch is performing as designed at the time of inspection. WARRANTY: 1 Year PARTS AND LABOR Unless otherwise stated on this document.


David R.

David R. Job Checkin

CONCERN: Customer reports ice maker is overflowing when making ice. DIAGNOSTIC AND CAUSE: Found the ice maker failing. CORRECTION: Replaced ice maker and tested. Operation now normal. No leaks upon completion. CONCERN: Customer reports refrigerator dispenser counter is off, causing oz reading wrong. CAUSE: Found dispenser water valve failing. CORRECTION: Replaced refrigerator dispenser water valve and tested, operation now normal. No leaks upon completion.


Spencer B.

Spencer B. Job Checkin

Service call, found bad main control board and heating element. Customer declined estimate.


David R.

David R. Job Checkin

CONCERN: Customer reports refrigerator is not getting cold. CAUSE: Found compressor failed, condenser line severely corroded. CORRECTION: Replaced compressor and receiver dryer, replaced corroded portion of condenser line, evacuated system and recharged with refrigerant. Operation now normal.


Spencer B.

Spencer B. Job Checkin

Found bad motor inverter control board. EST $449.80 pls tax. PART BACKORDER STATUS FROM GE. Eta ship date as of today September 12th.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports dishwasher is not draining. CAUSE: Garbage disposal plug not removed. CORRECTION: Tested dishwasher pump for proper voltage and inspected for restrictions. Found restriction at garbage disposal plug, removed plug and tested. Operation now normal.


Spencer B.

Spencer B. Job Checkin

CAUSE: Found refrigerator water filter housing failed. CORRECTION: Replaced refrigerator water filter housing and tested for leaks. Operation now normal. No leaks upon completion.